Welcome to visit,Guangzhou Xin Flying Digital Technology Co.,Ltd!
Precautions for ground wire of XinFlying sublimation printer
Release time:2020-12-15    Originate:This station
If ground wire is not connected correctly or ground wire is connected incorrectly, static electricity generated during work of XinFlying sublimation printer cannot be output, which may destroy print head and main board. So how to connect ground wire correctly, here is a summary of XinFlying sublimation printer manufacturer.
 
 
1. Ground wire of XinFlying sublimation printer should not be too long, preferably within 3-5 meters;
 
2. Connect to depth of 1.5-2m underground, and irrigate surrounding with salt water, which must be in contact with soil;
 
3. A ground wire must also be installed for computer of XinFlying sublimation printer, preferably a separate wire and not the same wire as XinFlying sublimation printer;
 
4. Grounding point cannot be shared with ground wire of building's lightning rod, nor can it be connected with ground wire of high-voltage electrical appliances;
 
5. Grounding wire on XinFlying sublimation printer should be on metal part of fuselage closest to motherboard;
 
6. Ground wire should be a mechanically strong single-strand copper wire or a coiled wire. Preferably copper wire with a diameter of 4mm or more;
 
7. Both ends of wire of XinFlying sublimation printer should be welded to wire pins, or fastened with bolts, do not loosen, otherwise it is easy to catch fire and damage XinFlying sublimation printer;
Copyright © 2017 广州鑫飞扬数码科技有限公司 | Privacy Policy